Volvo Main | Volvo Industrial | Volvo Website

Ratings: Genset | Stationary | Horizontal

GEnerating Set Engines 1500/r/min, 50 hz

Engine

Prime Power*

Maximum Standby Power*

Generator Efficiency

Emis-

sion

 

bhp

kWm

kWe

kVA

bhp

kWm

kWe

kVA

%

 

TD520GE**

101

75

68

85

111

83

75

94

91%

1

TAD520GE**

118

88

80

100

128

96

87

109

91%

1

TD720GE**

152

113

104

130

166

124

114

142

92%

1

TAD720GE**

177

132

121

152

194

145

133

167

92%

1

TD710G

190

142

131

163

209

156

144

179

92%

-

TWD710G

212

158

145

182

240

179

165

206

92%

1

TWD740GE

243

181

167

208

267

199

183

229

92%

1,2

TAD740GE

295

220

202

253

325

242

223

278

92%

1,2

TAD1030GE

302

225

207

259

357

266

245

306

92%

1,2

TD1210G

292

218

201

251

351

262

241

301

92%

-

TWD1210G

353

263

242

302

388

289

266

332

92%

1

TWD1211G

378

282

262

328

413

308

286

358

93%

-

TAD1231GE

409

305

284

355

451

336

312

391

93%

1,2

TAD1240GE

380

283

263

329

417

311

289

362

93%

1,3

TD1232GE

434

324

301

377

479

357

332

415

93%

1,2

TAD1241GE

433

323

300

375

475

354

329

412

93%

1,3

TWD1630G

472

352

327

409

524

391

364

455

93%

1

TAD1242GE

472

352

327

409

519

387

360

450

93%

1,3

TAD1630GE

536

400

376

470

590

440

414

517

94%

1,2

TAD1631GE

583

435

409

511

641

478

449

562

94%

1,2

 

Generating Set Engines 1800 r/min, 60 hz

Engine

Prime Power*

Maximum Standby Power*

Generator Efficiency

Emis-sion

 

bhp

kWm

kWe

kVA

bhp

kWm

kWe

kVA

%

 

TD520GE**

103

77

70

88

114

85

77

96

91%

2

TAD520GE**

123

92

84

105

136

101

92

115

91%

2

TD720GE**

154

115

106

132

170

127

117

146

92%

2

TAD720GE**

187

140

129

161

206

154

141

177

92%

2

TD710G

188

140

129

161

225

168

155

193

92%

-

TWD710G

223

166

153

191

263

196

180

225

92%

-

TWD740GE

278

207

190

238

306

228

210

262

92%

2

TAD741GE

278

207

190

238

306

228

210

262

92%

3

TAD740GE

306

228

210

262

337

251

231

289

92%

2

TAD1030GE

315

235

216

270

378

282

259

324

92%

2

TAD1031GE

349

260

239

299

382

285

262

328

92%

3

TD1210G

333

248

228

285

373

278

256

320

92%

-

TWD1210G

369

275

253

316

409

305

281

351

92%

-

TWD1211G

402

300

279

349

443

330

307

384

93%

-

TAD1231GE

402

300

279

349

443

330

307

384

93%

2

TAD1240GE

402

300

279

349

443

330

307

384

93%

3

TD1232GE

457

341

317

396

519

387

360

450

93%

2

TAD1241GE

461

344

320

400

507

378

352

439

93%

3

TWD1630G

508

379

352

441

581

433

403

503

93%

-

TAD1242GE

524

391

364

455

577

430

400

500

93%

3

TAD1630GE

587

438

412

515

646

482

453

566

94%

2

TAD1631GE

661

493

463

579

732

546

513

642

94%

2

Net engine performance according to ISO 3046, BS 5514, DIN 6271 and in general SAW J 1349 net power.

*For power definitions, see technical sales handbook.
**Tropical cooling system

Emissions

  • Complies with TA-luft emission regulation. TWD710G and TWD1210G require special adjustment.

  • EPA/CARB tier 1 emission certified/complaint.

  • EPA/CARB tier 2 emission certified

All engines (1,2, and 3) are designed to comply with the EU and US emission regulations. For current information concerning delivery and emission certificate status, refer to your local Volvo Penta distributor.