GEnerating
Set Engines 1500/r/min, 50 hz
|
Engine |
Prime Power* |
Maximum Standby Power* |
Generator Efficiency |
Emis-
sion |
| |
bhp |
kWm |
kWe |
kVA |
bhp |
kWm |
kWe |
kVA |
% |
|
|
TD520GE** |
101 |
75 |
68 |
85 |
111 |
83 |
75 |
94 |
91% |
1 |
|
TAD520GE** |
118 |
88 |
80 |
100 |
128 |
96 |
87 |
109 |
91% |
1 |
|
TD720GE**
|
152 |
113 |
104 |
130 |
166 |
124 |
114 |
142 |
92% |
1 |
|
TAD720GE** |
177 |
132 |
121 |
152 |
194 |
145 |
133 |
167 |
92% |
1 |
|
TD710G |
190 |
142 |
131 |
163 |
209 |
156 |
144 |
179 |
92% |
- |
|
TWD710G |
212 |
158 |
145 |
182 |
240 |
179 |
165 |
206 |
92% |
1 |
|
TWD740GE |
243 |
181 |
167 |
208 |
267 |
199 |
183 |
229 |
92% |
1,2 |
|
TAD740GE
|
295 |
220 |
202 |
253 |
325 |
242 |
223 |
278 |
92% |
1,2 |
|
TAD1030GE |
302 |
225 |
207 |
259 |
357 |
266 |
245 |
306 |
92% |
1,2 |
|
TD1210G |
292 |
218 |
201 |
251 |
351 |
262 |
241 |
301 |
92% |
- |
|
TWD1210G |
353 |
263 |
242 |
302 |
388 |
289 |
266 |
332 |
92% |
1 |
|
TWD1211G |
378 |
282 |
262 |
328 |
413 |
308 |
286 |
358 |
93% |
- |
|
TAD1231GE
|
409 |
305 |
284 |
355 |
451 |
336 |
312 |
391 |
93% |
1,2 |
|
TAD1240GE
|
380 |
283 |
263 |
329 |
417 |
311 |
289 |
362 |
93% |
1,3 |
|
TD1232GE |
434 |
324 |
301 |
377 |
479 |
357 |
332 |
415 |
93% |
1,2 |
|
TAD1241GE |
433 |
323 |
300 |
375 |
475 |
354 |
329 |
412 |
93% |
1,3 |
|
TWD1630G |
472 |
352 |
327 |
409 |
524 |
391 |
364 |
455 |
93% |
1 |
|
TAD1242GE
|
472 |
352 |
327 |
409 |
519 |
387 |
360 |
450 |
93% |
1,3 |
|
TAD1630GE
|
536 |
400 |
376 |
470 |
590 |
440 |
414 |
517 |
94% |
1,2 |
|
TAD1631GE
|
583 |
435 |
409 |
511 |
641 |
478 |
449 |
562 |
94% |
1,2 |
|
|
Generating Set Engines 1800 r/min, 60 hz
|
Engine |
Prime Power* |
Maximum Standby Power* |
Generator Efficiency |
Emis-sion |
| |
bhp |
kWm |
kWe |
kVA |
bhp |
kWm |
kWe |
kVA |
% |
|
|
TD520GE**
|
103 |
77 |
70 |
88 |
114 |
85 |
77 |
96 |
91% |
2 |
|
TAD520GE**
|
123 |
92 |
84 |
105 |
136 |
101 |
92 |
115 |
91% |
2 |
|
TD720GE**
|
154 |
115 |
106 |
132 |
170 |
127 |
117 |
146 |
92% |
2 |
|
TAD720GE**
|
187 |
140 |
129 |
161 |
206 |
154 |
141 |
177 |
92% |
2 |
|
TD710G |
188 |
140 |
129 |
161 |
225 |
168 |
155 |
193 |
92% |
- |
|
TWD710G |
223 |
166 |
153 |
191 |
263 |
196 |
180 |
225 |
92% |
- |
|
TWD740GE
|
278 |
207 |
190 |
238 |
306 |
228 |
210 |
262 |
92% |
2 |
|
TAD741GE |
278 |
207 |
190 |
238 |
306 |
228 |
210 |
262 |
92% |
3 |
|
TAD740GE |
306 |
228 |
210 |
262 |
337 |
251 |
231 |
289 |
92% |
2 |
|
TAD1030GE
|
315 |
235 |
216 |
270 |
378 |
282 |
259 |
324 |
92% |
2 |
|
TAD1031GE
|
349 |
260 |
239 |
299 |
382 |
285 |
262 |
328 |
92% |
3 |
|
TD1210G |
333 |
248 |
228 |
285 |
373 |
278 |
256 |
320 |
92% |
- |
|
TWD1210G |
369 |
275 |
253 |
316 |
409 |
305 |
281 |
351 |
92% |
- |
|
TWD1211G |
402 |
300 |
279 |
349 |
443 |
330 |
307 |
384 |
93% |
- |
|
TAD1231GE
|
402 |
300 |
279 |
349 |
443 |
330 |
307 |
384 |
93% |
2 |
|
TAD1240GE
|
402 |
300 |
279 |
349 |
443 |
330 |
307 |
384 |
93% |
3 |
|
TD1232GE |
457 |
341 |
317 |
396 |
519 |
387 |
360 |
450 |
93% |
2 |
|
TAD1241GE |
461 |
344 |
320 |
400 |
507 |
378 |
352 |
439 |
93% |
3 |
|
TWD1630G |
508 |
379 |
352 |
441 |
581 |
433 |
403 |
503 |
93% |
- |
|
TAD1242GE |
524 |
391 |
364 |
455 |
577 |
430 |
400 |
500 |
93% |
3 |
|
TAD1630GE
|
587 |
438 |
412 |
515 |
646 |
482 |
453 |
566 |
94% |
2 |
|
TAD1631GE
|
661 |
493 |
463 |
579 |
732 |
546 |
513 |
642 |
94% |
2 |
|
|
|
Net engine performance according to ISO 3046, BS 5514, DIN 6271
and in general SAW J 1349 net power.
*For power definitions, see technical sales handbook.
**Tropical cooling system
Emissions
-
Complies with TA-luft emission regulation. TWD710G and TWD1210G require
special adjustment.
-
EPA/CARB tier 1 emission certified/complaint.
-
EPA/CARB tier 2 emission certified
All engines (1,2, and 3) are designed to comply with the EU
and US emission regulations. For current information concerning delivery and
emission certificate status, refer to your local Volvo Penta distributor. |